01 · Proven before the outage

A Commercial Generator Is Only as Good as Its Last Test

Most commercial generators that fail in an outage were never tested under load. They start on the weekly exercise, idle for ten minutes and look fine, then shut down the first time the building actually leans on them. Our maintenance plans exist to find that problem on a Tuesday afternoon instead of at 2 a.m. in an outflow storm.

Every plan is aligned to CSA C282-19 for emergency power systems. We keep a digital or printed logbook, exercise the transfer switches and run the set under load, and you choose the cadence that fits your property and your authority requirements.

Who we look after

Strata buildings in Clearbrook with fire pumps and elevators, clinics and dental offices on South Fraser Way, downtown restaurants with walk-in coolers, wineries in Mt. Lehman, and poultry and dairy barns on Sumas and Matsqui Prairie where a failed generator means lost livestock.

Get a maintenance quote Call 24/7 · (604) 455-5765

Electrician testing breakers with a tester on a commercial panel
Commercial load test · parkade

24/7 generator line

(604) 455-5765

Speak to a rep. A technician follows.

02 · Monthly service

Monthly Service: Inspection and Functional Checks

The base plan for every commercial generator we maintain.

  • Check fluid levels: oil, coolant and fuel
  • Inspect for leaks and general cleanliness
  • Verify battery voltage and electrolyte levels
  • Confirm control panel indicators are normal
  • Start and run the generator (no load) to verify oil pressure, temperature and engine response
  • Record all observations and corrective actions in the maintenance log
  • Simulate a power failure and run the generator under load for at least 60 minutes at 30% of rated load or higher
  • Exercise and inspect the transfer switches
  • Check and drain exhaust condensate traps
  • Inspect belts, filters, battery charger and ventilation system
Crew member in a hard hat and harness on a power job
Licensed, insured, on site

Quarterly and annual add-ons

  • Oil, filter and coolant service on the run hours the manufacturer sets
  • Fuel quality check and tank inspection on diesel sets
  • Load bank test where the building load cannot reach 30%
  • Battery replacement on a schedule, not after a failure

Put your generator on a plan before the storm season.

03 · Why a plan

What a Maintenance Plan Gets You

01

A logbook that holds up

Every visit, reading and correction is recorded, ready for the fire inspector, the strata council or your insurer.

02

Real load, not idle

At least 60 minutes at 30% of rated load or more, so wet-stacking and weak parts show up early.

03

Transfer switches proven

We exercise and inspect every switch, because a generator that runs but never takes the load is no backup at all.

04

One 24/7 number

Plan customers call one line, day or night, and the tech already knows the machine.

We only do generators. The technician who services your set has commissioned hundreds of them, from 22 kW homes to three-phase barn sets.

  • Project managerLoad calculation, permits, FortisBC and BC Hydro coordination, schedule
  • Licensed gas fitterGas line and meter work to CSA B149.1, pressure-tested under load
  • ElectricianTransfer switch and wiring to the BC Electrical Code (CSA C22.1)
  • Service technicianCommissioning, live outage test, yearly maintenance
  • 24/7 coordinatorAnswers the phone at 2 a.m. and dispatches the tech
04 · Questions

Maintenance Plan Questions

How often should a commercial generator be serviced?

Monthly inspection and functional checks are the base plan. Higher-risk sites like clinics, stratas with life-safety loads and livestock barns usually add quarterly and annual work. We set the cadence to your property and to what your authority requires.

What does CSA C282-19 have to do with my generator?

CSA C282 is the Canadian standard for emergency electrical power supply in buildings. It sets out inspection, testing and record-keeping for emergency generators. Our plans follow it, including the logbook and the under-load run.

Do you run the generator under real load?

Yes. We simulate a power failure and run the generator under load for at least 60 minutes at 30% of its rating or more, then record oil pressure, temperature and voltage in the log.

Can you maintain a generator someone else installed?

Yes. We take over most makes, start with a full inspection and a load run, and give you a written list of anything that needs fixing before it is put on a plan.

Contact Us Today for a Free Estimate

Tell us about your commercial property and the equipment you need protected. Contact us for generator installation or repair assistance.

(604) 455-5765

Free quote: Commercial Generator Installation & Repair

Free. No obligation. We call you back, usually within a minute.

Call 24/7 · (604) 455-5765Free quote